The Start Switch must be activated within 60 seconds of advancing the throttle or the engine will not start. To reset, set Throttle to OFF and toggle the FADEC Circuit Breaker Switch OFF, then ON. Then restart the procedure.
Start Switch
Hold ON for 2 SECONDS then RELEASE
Pilot MFD may flicker as voltage drops during start process
Acknowledge cautions as necessary
NG
Wait to stabilize between 63-65%
DC Generator Switch
ON
AC Generator Switch
ON
Essential Bus Switch
RUN
Fuel Boost Switch
ON
Particle Separator Circuit Breaker
IN
Throttle
OPEN
MPD BIT/RESET Switch
RESET
MPD Selector Switch
NR/NP
RPM Trim Switch
INC to 100% NP/NR
At 100% NR a single amber chiclet should be visible on the NR Vertical Scale Indicator
13
After Engine Start
SCAS Power Switch
ON
SCAS Pitch/Roll Engage Switch
ON
SCAS Yaw Engage Switch
ON
MPD Selector Switch
FUEL QTY/ENG TRQ
IFF Circuit Breaker Switch
ON
Radar Detector Circuit Breaker Switch
ON
Radar Warning Circuit Breaker Switch
ON
AN/APR-39 and AN/AVR-2 powerup and self-tests will begin automatically
L2MUM Circuit Breaker Switch
ON
CMWS Circuit Breaker Switch
ON
CMWS Circuit Breaker Switch is located on a separate panel above and behind the pilot's head. Note that CMWS procedures are not applicable if AN/ALQ-144 IRCM is installed.
CMWS CI ON/OFF/TEST Knob
ON
AN/AAR-57 powerup and self-test begins automatically
CMWS Arm/Safe Switch
ARM
CMWS Auto/Bypass Switch
AS DESIRED
Copilot MFD
MMS
MMS Mode Selector
FWD
MMS Manual/Slave Switch
MANUAL, then SLAVED
MMS Laser Switch
As Desired
Master Arm Switch
STANDBY
Pilot MFD
VSD
NAV Alignment
Wait until complete
23
After Engine Start
NAV Alignment
Wait until complete
EGI alignment will start automatically in most cases. It will take a maximum of four minutes to align (and often much less time), during which time the VSD and HVR pages will display reduced information. The NAV NOT ALIGNED caution will disappear automatically upon successful alignment.